FabDigit

Steel SPCC · finish state

Steel SPCC Galvanized

Properties of the Galvanized condition, compared with the other SPCC tempers.

Standard choice when the part sees humidity or outdoor exposure without paint; zinc gives sacrificial protection but reduces weld electrode life and spatters.

Sheet metalBudget cost $

What is SPCC Galvanized?

SPCC Galvanized is SPCC supplied in the Galvanized condition — standard choice when the part sees humidity or outdoor exposure without paint; zinc gives sacrificial protection but reduces weld electrode life and spatters. SPCC Galvanized has a yield strength of 220 MPa (31.9 ksi) and a tensile strength of 320 MPa (46.4 ksi) — weaker than 98% of steel grades. Elongation at break is 34% and the elastic modulus is 205 GPa (29.7 Msi). SPCC Galvanized has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,495°C (2,723 °F). HR is the default condition FabDigit quotes; Galvanized is available on request or by drawing note.

Advantages

  • High electrical conductivity — 11 % IACS, better than 98% of steel grades
  • Good corrosion resistance — 35/100, better than 97% of steel grades
  • Ductile — tolerates forming and impact — 34%, better than 96% of steel grades
  • Forms and bends easily — 82/100, better than 94% of steel grades
  • Conducts heat well — 51 W/m·K (29.5 BTU/hr·ft·°F), better than 92% of steel grades

Limitations

  • Hard to polish — 30/100, worse than 100% of steel grades
  • Low strength — 220 MPa (31.9 ksi), worse than 98% of steel grades
  • Limited service temperature — 200°C (392 °F), worse than 93% of steel grades

SPCC Galvanized properties

Typical room-temperature values for SPCC Galvanized — 9 properties are specific to this condition; the rest are grade-level values shared by every SPCC temper. Each bar shows where the value sits among the steel grades in FabDigit's library — further right is higher.

Physical3

SPCC Galvanized has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,495°C (2,723 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,495°C2,723 °F
Liquidus Temperature1,530°C2,786 °F

Mechanical15

SPCC Galvanized has a yield strength of 220 MPa (31.9 ksi) and a tensile strength of 320 MPa (46.4 ksi) — weaker than 98% of steel grades. Elongation at break is 34% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)320 MPa46.4 ksi
Yield Strength (0.2% offset)220 MPa31.9 ksi
Elongation at Break34%
Reduction in Area65%
Compressive Strength195 MPa28.3 ksi
Shear Strength230 MPa33.4 ksi
Fatigue Strength (Endurance Limit)165 MPa23.9 ksi
Fracture Toughness (K_IC)110 MPa·√m100 ksi·√in
Hardness, Brinell100 HB
Hardness, Rockwell B52 HRB
Hardness, Vickers110 HV

Thermal6

SPCC Galvanized is rated for continuous service to 200°C (392 °F). It conducts heat at 51 W/m·K (29.5 BTU/hr·ft·°F), better than 92% of steel grades. Thermal expansion is 12 µm/m·K (6.67 µin/in·°F).

Thermal Conductivity51 W/m·K29.5 BTU/hr·ft·°F
Specific Heat Capacity480 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12 µm/m·K6.7 µin/in·°F
Latent Heat of Fusion272 J/g117 BTU/lb
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-20°C-4 °F

Electrical3

SPCC Galvanized conducts electricity at 11 % IACS, better than 98% of steel grades.

Electrical Conductivity11 % IACS
Electrical Resistivity1.6×10⁻⁷ Ω·m6.3 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is fair (35/100), better than 97% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.65 V
Corrosion ResistanceFair35/100
Chemical Resistance SummaryRusts rapidly in humid air, water or salt; attacked by all acids. Stable only in dry indoor air, oils, or under paint/zinc/tin coating; alkaline environments (pH 10–13, concrete) are benign.

Sustainability4

Producing a kilogram of SPCC Galvanized takes about 30 MJ of energy and emits 2.3 kg of CO₂ — more than 55% of steel grades. Typical recycled content is 25%.

Embodied Energy (primary production)30 MJ/kg12,898 BTU/lb
Embodied Carbon (primary production)2.3 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content25%

Manufacturability7

SPCC Galvanized's machinability is good (60/100, better than 83% of steel grades); weldability very good (70/100); formability very good (82/100).

MachinabilityGood60/100
Machinability Rating (AISI 1212 = 100 %)65%
WeldabilityVery good70/100
Formability (cold)Very good82/100
Brazeability / SolderabilityGood55/100
PolishabilityPoor30/100
Anodizing Responsen/a — ferrous alloy; use zinc/tin plating, phosphate + e-coat or powder paint instead

Values are nominal handbook figures for design screening. Certified mill or lot data ships with every FabDigit order on request.

Other SPCC tempers and conditions

SPCC is also supplied in 8 other conditions. The full side-by-side table is on the SPCC overview.

Working with SPCC Galvanized

Is SPCC easy to machine?

Soft and gummy — use sharp positive-rake tools, high speed and coolant; expect heavy burrs on punched/drilled sheet, plan deburring.

Can SPCC be welded?

Excellent for resistance spot, MIG/MAG and laser welding with ER70S-6 class wire; no preheat needed, but remove zinc/tin coating and ventilate fumes on coated variants.

Can SPCC be formed, bent or molded?

Standard temper draws, bends and roll-forms readily (bend radius ~0.5–1×t for SD/A temper); use SPCCD/SPCCE for severe draws and watch stretcher strain in non-skin-passed sheet.

What surface finishes work on SPCC?

Bare SPCC must be protected: zinc phosphate + e-coat/powder paint, electro- or hot-dip zinc, tin, or Ni/Cr plating; oiled surface must be degreased before painting.

SPCC chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
CJIS G3141 SPCC ladle analysis max≤ 0.150.06
Mn≤ 0.60.3
P≤ 0.10.02
S≤ 0.050.02
Altypical Al-killed deoxidation practice, not a JIS requirement0.02 – 0.070.04
Febalance

SPCC Galvanized — frequently asked

What is SPCC Galvanized used for?

SPCC Galvanized is typically used for sheet metal enclosures, PC and server chassis, appliance panels and covers, brackets and mounting plates, electrical cabinet doors and tinplate containers. In short: common commercial cold-rolled.

What is the yield strength of SPCC Galvanized?

SPCC Galvanized has a typical yield strength of 220 MPa (31.9 ksi) and a tensile strength of 320 MPa (46.4 ksi) — weaker than 98% of steel grades. Strength varies by condition: see the 9 listed tempers.

Is SPCC Galvanized easy to machine?

Reasonably — machinability is rated good (60/100, better than 83% of steel grades). Soft and gummy — use sharp positive-rake tools, high speed and coolant; expect heavy burrs on punched/drilled sheet, plan deburring.

Can SPCC Galvanized be welded?

Yes — weldability is rated very good (70/100). Excellent for resistance spot, MIG/MAG and laser welding with ER70S-6 class wire; no preheat needed, but remove zinc/tin coating and ventilate fumes on coated variants.

What surface finishes work on SPCC Galvanized?

Bare SPCC must be protected: zinc phosphate + e-coat/powder paint, electro- or hot-dip zinc, tin, or Ni/Cr plating; oiled surface must be degreased before painting.

Can SPCC Galvanized be formed, bent or molded?

Standard temper draws, bends and roll-forms readily (bend radius ~0.5–1×t for SD/A temper); use SPCCD/SPCCE for severe draws and watch stretcher strain in non-skin-passed sheet.

What is the maximum service temperature of SPCC Galvanized?

SPCC Galvanized is rated for continuous use to about 200°C (392 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between SPCC-HR and SPCC-CR?

HR is the default condition — use for thicker, less critical parts where cold-rolled surface and tight tolerances are not needed; SPCC itself is a cold-rolled grade, so this is the SPHC/hot-rolled analogue. CR: default stocking condition: annealed and skin-passed cold-rolled coil/sheet for general stamping, brackets and enclosures. Yield strength is 220 MPa in HR versus 195 MPa in CR.

Can FabDigit make parts in SPCC Galvanized?

Yes — SPCC Galvanized is available for sheet metal with instant online pricing. Upload a STEP file to get a price and a DFM check.

Sources

  1. JIS G3141 — Cold-reduced carbon steel sheets and stripJSA (2021)
  2. JIS G3302 — Hot-dip zinc-coated steel sheets and coils (SGCC)JSA (2019)
  3. JIS G3303 — Tinplate and blackplate (SPTE)JSA (2017)
  4. GB/T 5213 / GB/T 708SAC (2019)
  5. ASM Handbook Vol.1: Properties and Selection — Irons, SteelsASM International (1990)
  6. Machinery's Handbook, 31st ed. (machinability ratings)Industrial Press (2020)
  7. Cold-rolled coil datasheets (Nippon Steel / JFE / Baosteel SPCC)mill datasheets (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.